My Cart

Clever Pool Pump Inverter

Login to view prices
Availability : Call For Availability
SKU
CPI001

The Clever-Pool Inverter is a low cost solution designed to greatly reduce the running costs of pool circulation pumps and improve the efficiency of swimming pool filtration. Clever-Pools’ low capital outlay ensures that the typical capital payback period is less than 2 years.

Install on an existing pump or mount on a wall and then connect to your pump

  • Up to 60% savings on pool pump energy consumption
  • Simple installation
  • Manual and Auto mode
  • Compatible with 95% of single speed pumps up to 2hp
  • User friendly Control Panel
  • Reduced wear and tear on your pool pump
  • Reduced noise levels
  • Improved filtration
  • Set reduced speeds on your pump

The Clever-Pool Inverter is a low cost solution designed to greatly reduce the running costs of pool circulation pumps and improve the efficiency of swimming pool filtration. Clever-Pools’ low capital outlay ensures that the typical capital payback period is less than 2 years.

Swimming pool pumps invariably run at higher flow rates than necessary. Clever-Pool Inverter technology enables you to control both pump flow-rates and pump run times. Clever-Pool transforms conventional pool circulation pumps into ‘variable speed’ pumps resulting in huge savings in energy costs.

Clever-Pool is CE approved, simply connect the Clever-Pool (via an RCD) to the mains supply in the plant-room and wire the circulation pump into the Clever-Pool. Installation typically takes less than 30 minutes. Clever-Pool has 4 timer programmes during a 24 hour cycle that can be set to suit your requirements.

Low For pool water filtration
Medium For use with automatic suction cleaners
High For increased water flow for a limited period
Backwash Maximum pump output for thorough cleaning of filter media

An additional benefit of installing a Clever Pool is improved pool water clarity. Recent studies have concluded that pushing excessive volumes of water through ‘high rate’ sand filters can result in ineffective filtration. Larger quantities of suspended particles can be captured by filter-media when pool water is percolated at a slower rate for a limited period each day.

It is impossible to give an exact calculation with regards to potential energy savings; each pool is different and a multitude of parameters need to be factored. For example, the cost per kilowatt of energy, the size of your pool circulation pump and the number of months per year that a pool pump is operated vary from pool to pool. The remarkable thing about Inverter technology is energy savings reduce at an extraordinary rate as your pool water pump flow is reduced. For example, if you run your pool pump at 50% of its maximum output you will experience an energy reduction of 75%! It’s not difficult to see why the capital cost of a Clever-Pool can be recovered in such a short period.

More Information
SKUCPI001
Re-stock dateCall For Availability
Discount GroupK
Pump RangePump Inverter
Customer Questions
Is the CPI001 Clever Pool Pump Inverter compatible with a Certikin Aqua Speed 1.5hp Pump?
If the Certikin Aqua Speed 1.5hp Pump is a single-phase, single-speed model, then yes, it is compatible with the CPI001 Clever Pool Pump Inverter. However, if it is a three-phase model or one of the Aquaspeed ECO-V Variable Speed Pumps 5, then it is ...
Is the Clever Pool Inverter CPI001 compatible with the Dura Class Model 5P2R5F single phase, 11/2 hp, 1.1kw Sta-rite pump?
The Dura Class Model 5P2R5F single-phase, 1.5 hp, 1.1 kW Sta-rite pump is indeed compatible with the Clever Pool Inverter CPI001.
What does error code OLP mean on a Clever Pool Pump Inverter?
Error code "OLP" on a Clever Pool Pump Inverter refers to "Overload Protection." This code is triggered when the inverter detects an overload condition in the connected equipment, such as the pump. It's a safety feature that prevents damage to the components...
My Clever Pool Pump Inverter operates in low, medium or high mode, the pump has an unpleasant noise, it is normal when in backwash mode?
When the Clever Pool Pump Inverter operates in low, medium, or high mode, it's not uncommon for some pumps to produce a different noise compared to their standard operating sound. Slowing down the pump can sometimes cause it to emit a humming or buzzing...
Is a clever-pool pump inverter compatible with a 2hp Astral Victoria Plus Silent single phase?
Yes, the Clever Pool Pump Inverter is compatible with the 2hp Astral Victoria Plus Silent single-phase pump. It's designed to work with 95% of single-speed pumps, and although a complete list of compatible pumps isn't available, the specifications and...
Why does the inverter not change the pump speed?
The Clever Pool Pump Inverter always starts at full speed allows the system to be primed, ensuring that the pump is fully filled with the fluid it's moving, and that any air is removed from the system. This full-speed priming process generally takes ...
Can the Clever Pool Pump inverter run two pumps?
No, the Clever Pool Pump inverter is designed to control a single pump. Running two pumps would require separate control for each, as the inverter needs to be matched to the specific requirements of the pump it's controlling. The specifications and power...
Is the Clever-Pool Pump Inverter suitable for a 750W pump?
The Clever-Pool Pump Inverter is compatible with 95% of single speed pumps up to 2.0hp.
Why does the Clever Pool inverter start at Max speed every time it is switched on?
The Clever Pool inverter starts at the maximum speed every time it's switched on to prime the system effectively. Priming ensures that the pump is fully filled with water and all the air is expelled from the system before it begins normal operation. ...
Would using the Clever Pool save a 1/3 of the the amount quoted in the literature?
The Clever Pool Pump Inverter is designed to allow the pump to run at different speeds, potentially offering significant energy savings compared to running a pump at full speed all the time. However, the actual savings can vary based on several factors...
You must be logged in to submit a question